Products
Building Material Power Tools Hand Tools Architectural Hardware Safety Products Electrical Products - Conduit Pipes - Cable Trunkings - Bends - Connector Bars - Single Core Cables - Auto Cables - Welding Cables - Telephone Cables - Fans - Two Core Cables - Coaxial Cables - Control Cables - Panel Wires (PVC Insulated Cables) - Screen Cables - LED Bulbs - LED Panel Lights - Tube Lights - Flood Lights - Residual Current Circuit Breakers - Miniature Circuit Breakers - Switch Disconnectors - Electric Isolaters - Circuit Breakers (Fixed Type) - Circuit Breakers (Adjustable Type) - Contactor - D Range - Overload Relay - D Range - LED Indicators - Push Buttons - Electric Mechanical Interlocks - Timer Switches - Power Energy Meters - Four Core Cables - Five Core Cabels - Wall Mounting Enclosures Cast Iron Products Powertool Accessories Plumbing Products PVC Products Rubber Products General Hardware Chemical Products Painting Products230v Contactor Price In Sri Lanka
30% OFF
Rs. 89,362.00 Rs. 68,740.00
Model No: LC1DT60AP7
Brand: Schneider
Call now
0774 953 653 | 0777 731 670 | 0771 200 201
Share
Brand - Schneider
Model - LC1DT60AP7
Range - TeSys
TeSys Deca
Range of Product - TeSys Deca
Product or Component Type - Contactor
Device short Name - LC1D
Contactor Application - Resistive Load
Utilisation category - AC-1
AC-3
AC-3e
AC-4
Poles Description - 4P
[Ue] Rated operational voltage - Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] Rated operational current - 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] Control circuit voltage - 230 V AC 50/60 Hz
Complementary
Compatibility code - LC1D
Pole contact composition 4 - NO
Protective cover - With
[Ith] conventional free air thermal current - 10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity - 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity - 800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current - 320 A 40 °C - 10 s for power circuit
720 A 40 °C - 1 s for power circuit
72 A 40 °C - 10 min for power circuit
165 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating - 10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance - 1.6 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole - 5.8 W AC-1
[Ui] rated insulation voltage - Power circuit: 600 V CSA certified
Power circuit: - 600 V UL certified
Signalling circuit: - 690 V conforming to IEC 60947-1
Signalling circuit: - 600 V CSA certified
Signalling circuit: - 600 V UL certified
Power circuit: - 690 V conforming to IEC 60947-4-1
Overvoltage - category III
Pollution degree - 3
[Uimp] rated impulse withstand voltage - 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO
13849-1
Mechanical durability - 6 Mcycles
Electrical durability - 1.4 Mcycles 25 A AC-1 at Ue <= 440 V
Control circuit type - AC at 50/60 Hz
Coil technology - Without built-in suppressor module
Control circuit voltage limits - 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA - 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA - 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation - 4…5 W at 50/60 Hz
Operating time - 4...19 ms opening / 12...26 ms closing
Maximum operating rate - 3600 cyc/h 60 °C
Maximum operating rate - 3600 cyc/h at 60 °C
Auxiliary contact composition 1 - NO + 1 NC
Auxiliary contacts type - type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency - 25...400 Hz
Minimum switching voltage - 17 V for signalling circuit
Minimum switching current - 5 mA for signalling circuit
Insulation resistance - 10 MOhm for signalling circuit
Non-overlap time - 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
mounting support - Plate Rail
IP degree of protection - IP20 front face conforming to IEC 60529
Protective treatment - TH conforming to IEC 60068-2-30
Climatic withstand - conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude - 0...3000 m
Fire resistance - 850 °C conforming to IEC 60695-2-1
Flame retardance - V1 conforming to UL 94
Mechanical robustness - Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height - 122 mm
Width - 70 mm
Depth - 120 mm
net weight - 1.09 kg
Packing Units
Unit Type of Package 1 - PCE
Number of Units in Package 1 - 1
Package 1 Height - 7.500 cm
Package 1 Width - 13.500 cm
Package 1 - Length 15.000 cm
Package 1 - Weight 1.090 g
Unit Type of Package 2 - S02
Number of Units in Package 2 - 7
Package 2 Height - 15.000 cm
Package 2 Width - 30.000 cm
Package 2 Length - 40.000 cm
Package 2 Weight - 8.204 kg
Unit Type of Package 3 - P06
Number of Units in Package 3 - 112
Package 3 Height - 75.000 cm
Package 3 Width - 60.000 cm
Package 3 Length - 80.000 cm
Package 3 Weight - 139.264 kg
18 Months Company Warranty